Installation
Installation
The MA6600 can be placed upright on a table or
shelf, standing on its four feet. It also can be custom
installed in a piece of furniture or cabinet of your
choice. The four feet may be removed from the bottom
of the MA6600 when it is custom installed as out-
lined below. The four feet together with the mounting
screws should be retained for possible future use if the
MA6600 is removed from the custom installation and
used free standing. The required panel cutout, ventila-
tion cutout and unit dimensions are shown.
Always provide adequate ventilation for your
MA6600. Cool operation ensures the longest possible
operating life for any electronic instrument. Do not
install the MA6600 directly above a heat generat-
ing component such as a high powered amplifier. If
all the components are installed in a single cabinet, a
quiet running ventilation fan can be a definite asset in
maintaining all the system components at the coolest
possible operating temperature.
A custom cabinet installation should provide the
following minimum spacing dimensions for cool
operation.
Allow at least 6 inches (15.24cm) above the top, 2
inches (5.08cm) below the bottom and 1 inch (2.54cm)
on each side of the Integrated Amplifier, so that air-
flow is not obstructed. Allow 20 inches (50.8cm) depth
behind the front panel. Allow 2-1/4 inch (5.72cm) in
front of the mounting panel for handle clearance. Be
sure to cut out a ventilation hole in the mounting shelf
according to the dimensions in the drawing.
SOURCE: CD1
15%
6 -5/8"
16.83cm
17-1/16"
43.34cm
Cutout Opening for Custom Mounting
MA6600 Front Panel
Custom Cabinet Cutout
Cutout
Opening
for
Ventilation
Cutout Opening for Ventilation
Support
Shelf
Cabinet
Front
Panel
Chassis
Spacers
MA6600 Side View
in Custom Cabinet
MA6600 Bottom View
in Custom Cabinet
14-1/2"
36.83cm
1"
2.54cm
6"
15.24cm
Opening
for Ventilation
13"
33.02cm
15-1/16"
38.26cm
2"
5.08cm
Note: Center the cutout Horizontally
on the unit. For purposes of
clarity, the above illustration
is not drawn to scale.
13-5/16"
33.81cm